Guralp-systems CMG-5T Instrukcja Użytkownika Strona 11

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 25
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 10
Operator's Guide
The primary gain block of the 5T is normally set at × 1 (unity). If
higher sensitivity is required, the gain of the instrument can be altered
by inserting gain-setting resistors onto the power supply board of the
unit:
If G is the gain change you require, then the value of the resistors to
insert is given by the formula
R = 10000 / (G – 1)
Care must be taken when soldering these resistors to the circuit board,
as overheating the terminal could easily damage surrounding circuit
elements.
December 2009 11
Przeglądanie stron 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 24 25

Komentarze do niniejszej Instrukcji

Brak uwag